Electrical Network Load Monitor, Analyzer, for Energy Consumption Control, Recording & Preventive Maintenance.

Electrical Network Load Monitor, Analyzer, for Energy Consumption Control, Recording & Preventive Maintenance.

"SMART"  Power Meter For: Electrical Load & Consumption Monitoring.

Equipment  Load  Monitoring on 3 phase 4 wire power supply  panels & electrical network distribution systems.                               

PTInc series Din Rail Multi-Energy Meters are designed to measure & record  the active, reactive and apparent power values and active and reactive energy values of a network.

 

 A Wealth of Information from a Low Cost Device you can afford!

 

 Key Features of our Electrical Network Monitoring Meter:

 

  • On Board Data Logging

  • Flexible, Upgradable Module Design (I/O and Communication)

  • Multi Communication Ports (Ethernet, RS485, Profibus)

  • Advanced LCD Display

  • Open MODBUS Protocol

  • True-RMS Measuring Parameters

  • 4-Quadrant Energy

  • Power Quality Analysis

  • Over Limit Alarm

  • Web Server and Email Sending

  • Switch Status Monitoring

  • Remote Switch Controlling

 

 Characteristics:

 

  • Internet ready-web accessible
    HTTP Web page browse, email sending on time interval or on event

  • True-RMS measuring parameter
     

  • 4-quadrant Energy
     

  • Power Quality Analysis
     

  • Over range alarm
     

  • Energy pulse output

Metering

  • Voltage V1, V2, V3.
     

  • Current I1, I2, I3, In, Iavg
     

  • Power P1, P2, P3, Psum
     

  • Reactive Power Q1, Q2, Q3, Qsum
     

  • Apparent Power S1, S2, S3, Ssum
     

  • Frequency F
     

  • Power Factor PF1, PF2, PF3, PF
     

  • Energy Ep_imp, Ep_exp, Ep_total, Ep_net
     

  • Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
     

  • Apparent Energy Es
     

  • Demand Dmd_P, Dmd_Q, Dmd_S

Monitoring

  • Power Quality
     

  • Voltage Harmonics and THD
     

  • Current Harmonics and THD
     

  • Voltage Crest Factor
     

  • THFF (TIF)
     

  • Current K Factor
     

  • Voltage Unbalance Factor U_unbl
     

  • Current Unbalance Factor I_unbl
     

  • Max/Min Statistics with Time Stamps

Alarms

  • Limits can be set for up to 16 indicated parameters and can be set with a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 44 parameters available.

I/O option module

  • The E-module® adds flexibility and easy expansion of the I/O functions. A maximum of 8 modules can be used for one meter. Digital input, digital output, pulse output, relay output, analog input and analog output are provided by I/O option module.

Display

  • Clear and large character LCD Screen display with white back light
    Wide environmental temperature endurance
    Display Load percentage, 4 quadrants power and load nature

 

 Product Description:

 

We offer Data Logging power meters with a broad range of metering and monitoring capabilities.  We are bringing a truly powerful and flexible data logging metering option to the market at a price point that will meet any budget.

 

 

 Specifications:

 

Metering

Parameters

Accuracy

Resolution

Range

Voltage

0.2%

0.1V

20V~500kV

Current

0.2%

0.001A

5mA~50000A

Current Demand

0.5%

1W

-9999MW~9999MW

Power

0.5%

1Var

-9999MVar~9999MVar

Reactive Power

0.5%

1VA

-9999MVA~9999MVA

Apparent Power

0.5%

1W

-9999MW~9999MW

Power Demand

0.5%

1Var

-9999MVar~9999MVar

Reactive Power

0.5%

1VA

-9999MVA~9999MVA

Power Factor

0.5%

0.001

-1.000~1.000

Frequency

2.0%

0.01Hz

45.00~65.00Hz

Energy

Primary

0.5%

0.1kWh

0-99999999.9kWh

Secondary

0.5%

0.001kWh

0-999999.999kWh

Reactive Energy

Primary

0.5%

0.1kvarh

0-99999999.9kVarh

Secondary

0.5%

0.001kvarh

0-999999.999kVarh

Apparent Energy

Primary

0.5%

0.1kVAh

0-99999999.9kVAh

Secondary

0.5%

0.001kVAh

0-999999.999kVAh

Harmonics

2.0%

0.1%

0.0%~100.0%

Phase Angle

2.0%

0.1°

0.0°~359.9°

Imbalace Factor

2.0%

0.1%
 

0.0%~100.0%

Running Time

 

0.01h

0~9999999.99h

Comminications

RS-485 (Option)

RS485, Modbus™ RTU Protocol
2-wire connection,
Up to 38400 baud rate

Ethernet (Optional)

10M/100M BaseT
MODBUS TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically

 

 

 

 

 

 

 

Search site

Contact

PRIME TECHNOLOGIES Inc. (PTInc) Patrijsweg #9. Cas Cora. Willemstad, Curacao N.A. Office.: (5999) 736-1353 Fax: (5999) 737-1553

                 

 

 